EMT 12500 Series
125W AC/DC Converter
|
|
 |
Compact (100x100x68mm) |
 |
Wide Input Range |
 |
12,15, 24V |
 |
Parallel able |
 |
Easy Mounting |
 |
Solid ALU Housing |
|
|
|
SPECIFICATIONS |
|
GENERAL |
|
| INPUT VOLTAGE |
85 -
265 VAC |
|
P/S CAPACITY |
< 1,2 nF
PRIM/SEC |
| 120 -
375 VDC |
ISOLATION |
PRIM/SEC
3750 V |
| INPUT
POWER |
<
110VA |
CREEPAGE |
8 mm |
| FILTER |
HIGH EFFICIENCY COMMON MODE |
EMC |
EN55022
- VDE 0871 |
| SAFETY |
IEC
950, EN 60950 |
| FUSE |
T 2,0
A |
PREFUSING
|
MAX 30 A |
| INRUSH |
<
20 A |
DERATING |
0
- 50° C NONE |
| INPUT
FREQ. |
45 -
65 Hz |
MTBF |
> 450.000 Hours |
| PROTECTION |
275
VAC VARISTOR |
OUTLINE |
100 x100 x 68
mm |
| EFFICIENCY |
79 - 86
% |
WEIGHT |
APPR.
525 g |
| FREQUENCY |
Appr.
70 Khz |
OPERATING |
0 - 55
° C See FIG. 2 |
| HOLD-UP TIME |
>
20 mSec. |
STORAGE |
-40 - +85 ° C |
OUTPUT |
|
| TYPE: |
EMT12512 |
EMT
12524 |
EMT
12548 |
| VOLTAGE |
+12 VDC |
+24
VDC |
+48 VDC |
| POWER |
100 W MAX |
125
W MAX |
125 W MAX |
| CURRENT LIMIT |
8,0 A See Curve
FIG.3 |
5,2
A See Curve FIG.3 |
2,5 A See Curve
FIG.3 |
| ADJUST RANGE |
11,8 - 13,8 VDC |
23,5
- 27,6 VDC |
47,0 - 55,2 VDC |
| RIPPLE |
< 1,0 % |
< 0,8 % |
< 0,8 % |
| LOAD REG. |
< 1,5 % |
< 1,0 % |
< 0,8 % |
| LINE REG. |
< 0,1 % |
< 0,1 % |
< 0,1 % |
| PARALLEL OPR. |
80 % POWER SHARE |
90 % POWER SHARE |
90 % POWER SHARE |
| FACTORY ADJUST |
12,10 VDC +/-0,01V @
0 A |
24,10 VDC +/-0,01V @
0 A |
48,10 VDC
+/-0,01V @ 0 A |
|
|
|
|
| Battery
Charging: |
By
charging Lead Acid Batteries, adjust unit to shown charge voltage with no load connected.
This will keep your Battery charged to 90 - 96% under normal temp. conditions, in normal
standby operation.Or contact your local Battery
Supplier, for technical information around Charge Voltage in Standby Operation and
readjust unit to desired voltage, with no Load. |
|
CHARGE VOLTAGES |
| Batt |
Volts |
| 12V |
13,8 V |
| 24V |
27,6 V |
| 48V |
55,2V |
|
|
| Parallel Operation: |
|
| When connecting
in parallel, use the same wire diameter/length from unit to common tie point, to best
parallel performance. Units are factory adjusted, to
above voltages, to optain best performance in parallel operation, - - if this adjustment
is changed, readjust unit's to wanted Output voltage (+/- 10mV) with no Load for each
unit, before connecting in parallel. |
|
|

|
Current Limit: Looking at Fig. 4, a typical Current Limit is shown together with
Toggle Mode point.
This point is at 40 - 60 % of rated Output Voltage on all
units.
When unit reaches its Toggle Mode point, unit will stop,
and with its automatically restart within seconds, unit will in this mode stand a constant
short with no damage or internal power losses.
|
|

|

|
| |
|
Dimensions: |
 |
|
|